The six major safety and emergency‑evacuation systems in coal mines are the core infrastructure for ensuring the safety of underground workers. They comprise a monitoring and surveillance system, a personnel positioning system, an emergency refuge system, a compressed‑air self‑rescue system, a water‑supply rescue system, and a communication‑liaison system. The following provides a detailed overview of each system:

I. Monitoring and Surveillance System

  • Functionality : Enables dynamic monitoring of underground coal mine environmental parameters such as gas and carbon monoxide concentrations, temperature, and wind speed, as well as real-time monitoring of equipment status.
  • Function When monitoring data exceed the threshold, the system automatically triggers an alarm and implements emergency measures such as power shutdown and personnel evacuation to prevent accidents like gas explosions.
  • composition : Includes sensors, actuators, substations, power supply units, master stations, host computers, system software, and other equipment.

II. Personnel Positioning System

  • Functionality : By having personnel entering the mine carry identification cards, real-time monitoring of the dynamic distribution and changes in underground personnel can be achieved.
  • Function In emergency situations, accurately determining personnel locations provides a basis for emergency rescue operations, helps curb overcapacity production, and prevents unauthorized entry into hazardous areas.
  • composition : Includes identification cards, location-monitoring substations, power supply units, transmission interfaces, host computers, system software, and other equipment.

III. Emergency Evacuation System

  • Functionality : Provide shelters and facilities for individuals who are unable to evacuate to safe areas in the event of a disaster.
  • Function : Ensure the safety of personnel during a disaster and await rescue.
  • composition : These include temporary refuge chambers, permanent refuge chambers, and life‑support capsules. Such refuge facilities shall be equipped with essential functions such as safety protection, oxygen supply, harmful gas removal, environmental monitoring, communications, lighting, power supply, and life‑support systems. Under conditions of no external support, their rated protection duration shall be no less than 96 hours.

IV. Compressed-Air Self-Rescue System

  • Functionality : During a disaster, it supplies compressed air to mining operation sites and provides vital oxygen to personnel at the accident scene.
  • Function : Prevent personnel from suffocating and ensure their respiratory safety.
  • Settings Air compressors are generally installed at the surface; in deep mines with multiple horizontal levels, they may be mounted in a safe and reliable location at the bottom-of‑shaft yard of the air‑supply level, two levels above the working face. Working faces in outburst-prone mines must be equipped with compressed-air self-rescue devices.

V. Water Supply and Rescue System

  • Functionality : Ensure that on-site personnel have access to water in the event of fires, explosions, or other emergencies.
  • Function : Provide potable water and fire‑fighting water to ensure the basic survival needs of evacuees.
  • Settings Coal mines must establish comprehensive dust-control water-supply systems in accordance with the requirements of the Coal Mine Safety Regulations, and install water supply valves at all mining faces and other locations where personnel are concentrated.

VI. Communication and Liaison System

  • Functionality : Ensure the smooth and effective transmission of critical information during rescue operations in the event of an accident.
  • Function : Ensure seamless communication between surface and underground operations and across all work sites, providing accurate information for disaster prevention, mitigation, and rapid emergency response and relief efforts.
  • Composition and Setup : These include mine dispatch communication systems, mine broadcast communication systems, mine mobile communication systems, and mine disaster‑relief communication systems. Telephones shall be installed in key electromechanical equipment chambers—such as the main and auxiliary shaft winding rooms, the shaft bottom yard, the transportation dispatch room, the mining area substations, and the pump rooms—as well as at working faces, in mining areas, and at the highest points of each level. Underground refuge chambers, underground main pump rooms, underground central substations, working faces in outburst‑prone coal seams, and designated assembly points for personnel evacuation during blasting must all be equipped with direct‑dial telephones connecting to the mine dispatch center.