When installing a personnel positioning system, never place base stations in these three types of locations.
Category:
Author:
Aviation and Optical-Electronic Technology
Source:
www.hangfeigd.com
Release Date:
2026-04-25
Office testing is normal, but positioning becomes inaccurate once you enter the workshop? An incorrect base station location can severely compromise device performance.
Many companies find that their office‑based personnel‑location systems perform flawlessly during testing, but once deployed in real industrial settings, they suffer from positioning drift, severe latency, or even signal loss. This isn’t necessarily a defect in the equipment itself; more often, it stems from improper placement of the base stations. As the signal‑receiving nodes of the positioning system, poorly chosen locations can introduce significant errors into the subsequent data.
Based on multiple field measurement cases and engineering summaries, the following… 3 When installing the personnel positioning system, base stations should be avoided.
Category 1: Areas densely populated with metal, where signals are prone to reflection interference, causing positioning jitter.
Common manifestations of this type of location include:
- When the subject is at rest, the positioning point continues to jitter erratically.
- The recorded motion trajectory shows back-and-forth reversals or abrupt jumps, which do not match the actual situation.
- A regional alarm was triggered erroneously; personnel have entered the hazardous area, yet the system indicates they are in a safe zone.
Cause Analysis:
When a positioning signal encounters a metallic surface, it undergoes strong reflection. As a result, the base station receives both the direct signal and multiple reflected signals, making it difficult to accurately determine the true location and leading to significant errors in positioning calculations.
Actual Measurement Case:
A certain mechanical processing plant has mounted a base station less than 2 The location of the rice. After the equipment was put into operation, indoor positioning data remained consistently abnormal: personnel from… A Point to walk to B At the location, the trajectory on the map kept jumping around. On-site inspection revealed that the area was densely covered with large stainless-steel panels and several heavy metal devices, causing the base station signal to undergo multiple reflections and resulting in multipath interference. After relocating the base station to maintain a distance of at least half a meter from the metallic objects, positioning returned to normal.
Suggestion: Base station antennas should not be mounted directly against metal pipes, steel columns, or large equipment. When conditions permit, maintain a minimum clearance of… 30 to 50 Centimeter-level spacing. If the site has dense metal interference and cannot be avoided, a professional-grade base station with multipath suppression capabilities should be selected.
Category 2: Near strong electromagnetic interference sources, signal quality degrades, and positioning errors increase exponentially.
Several consequences caused by strong electromagnetic interference:
- Positioning errors are significantly amplified; empirical measurements indicate that, in the vicinity of the interference source, positioning errors may increase. 12 More than double.
- Data refresh latency is severe: personnel have already left a given area, yet the system has not updated their location.
- The positioning card frequently disconnects, and the backend indicates that the device is offline, making continuous monitoring impossible.
Common sources of interference include:
High‑power wireless routers, industrial Bluetooth devices, two‑way radios, high‑frequency welders, large variable‑frequency drives, and older fluorescent lamp ballasts, among others. The electromagnetic emissions from these devices can interfere with positioning signals, leading to packet loss in mild cases or rendering base stations unable to process signals properly in severe cases.
Actual Measurement Case:
During a routine patrol, workers at a chemical industrial park experienced positioning lags, with the backend location updates remaining stuck for extended periods after personnel moved. After conducting spectrum analysis, technicians identified a high-power radio station and several high-frequency walkie-talkies in the vicinity of the base station. The positioning system repeatedly retransmitted data packets, causing congestion at the base station and resulting in latency that at one point exceeded 20 Seconds. Relocate the base station away from the interference source. 15 After relocating the antenna away from the rice and adding a filter at the antenna terminal, the issue was resolved.
Suggestion: An electromagnetic environment scan should be conducted prior to installation. If it is not possible to avoid strong interference sources on site, it is recommended to select base station equipment equipped with hardware filtering and anti‑interference circuitry.
Category 3: Thick concrete structures and underground areas, where signal attenuation is severe and blind spots are prone to occur.
Concrete walls significantly attenuate signals. A typical concrete wall can reduce signal strength by more than half; and when encountering load-bearing walls, steel reinforcement mesh, or multiple layers of floor slabs, the signal may be completely blocked.
Actual Measurement Case:
After a nursing home installed base stations in its underground cafeteria and bathing area, caregivers reported that the system was unable to track residents when they entered these zones. On-site measurements revealed that the base stations had been mounted within a thick corridor mezzanine, flanked by load-bearing walls and densely reinforced concrete columns. Additionally, the basement’s stone flooring and metal kitchen equipment further attenuated the signal. Once engineers relocated the base stations to an unobstructed, elevated area adjacent to a lightwell, the positioning blind spots in the underground spaces were eliminated, and the continuity of staff and resident movement trajectories was restored.
Installation Principles: Base stations should be installed at a height above ground. 3 to 8 At elevated locations, try to avoid signal shadow zones created by multiple walls. If the basement cannot achieve a direct line-of-sight path, consider installing additional repeaters or adding supplementary antenna sites at entrances and key areas.
Potential Real-World Risks Caused by Incorrect Base Station Locations
An incorrect selection of base station locations not only degrades positioning accuracy but may also have serious consequences in safety-critical scenarios.
A real-world lesson from a chemical engineering scenario:
After a large chemical park deployed a personnel‑location system, operators entering high‑hazard equipment areas did not trigger an alert, and the backend indicated that they were still in a safe zone. Repeated troubleshooting revealed that the base stations had been installed next to steel columns of the equipment framework; the signals, after multiple reflections off the steel structure, resulted in path errors. Although the personnel had already activated the boundary alarm, the system, relying on the erroneous signal, concluded that they had not entered the hazardous area. In the event of a leak or accident, such incorrect location data during emergency evacuations could severely disrupt rescue operations and command coordination.
During the course of providing aerial photovoltaic services to clients, engineers insist that each base station location must undergo on-site surveying and signal assessment, and no arbitrary placement is permitted. As a company with many years of experience in personnel positioning and possessing over… 3500 As a vendor with extensive experience in deploying complex scenarios, Hangfei Optoelectronics conducts electromagnetic‑environment and signal‑attenuation measurements using specialized instruments prior to delivery, and rigorously validates each candidate site. Whether in workshops densely packed with metal components or in petrochemical plants built with reinforced‑concrete structures, only when base station locations are appropriately selected can subsequent functions—such as electronic fencing, emergency rescue, and routine management—operate reliably.
Summary
When installing a personnel positioning system, selecting the optimal locations for base stations is the first critical step—and one that is often overlooked.
- Metal-dense area: Signal reflections cause positioning jitter.
- Strong electromagnetic interference zone: signal quality degrades, errors increase, and latency rises.
- Thick concrete and underground areas: Signal attenuation is severe, making blind spots common.
Even with the same equipment, scientifically planned placement versus haphazard positioning can lead to markedly different performance outcomes. If you’re planning to deploy a personnel‑location system, or if your existing system is underperforming in complex environments, we recommend reassessing the installation locations of your base stations.
(For on-site surveys, electromagnetic environment assessments, or base station deployment optimization, please contact us to learn more about our professional services.)