2026 year 7 month 1 On [date], the Ministry of Emergency Management released the “...” “ Industrial Internet + Safety in the Production of Hazardous Chemicals ” Construction Standards No. 3 Section: Personnel Positioning》( AQ 3064.3-2025 ) will be officially implemented. This means that personnel positioning systems have transitioned from an optional measure for chemical enterprises to a mandatory requirement. With a variety of positioning technologies available on the market, how to make a scientifically sound selection and ensure that the system is both secure and compliant while remaining stable and reliable has become a critical issue that safety managers in chemical companies must address with due diligence.
Among all selection criteria, explosion-proof certification is the most fundamental requirement, as it directly determines whether a system can be installed and operated within the plant premises.
1. Explosion-proof certification is the primary requirement; without it, the system cannot be put into operation.
Explosive gases and combustible dusts are present in the chemical plant, making it a high-risk environment. Equipment is deployed in explosive hazardous areas ( 1 district, 2 Any electronic device in the district, including positioning base stations and personnel‑worn positioning tags, must comply with GB 3836 Explosion-proof standards and GB 50058 Standards. If the hardware equipment has not been certified by a nationally authorized explosion-proof testing agency, the entire system will not meet the regulatory requirements for deployment in production environments and will fail to pass acceptance inspection.
The design principle of intrinsically safe equipment is to control energy at the circuit level, ensuring that neither sparks nor high temperatures capable of igniting a surrounding flammable gas atmosphere can occur under normal operating conditions or in the event of a single fault. Commonly found on certificates… Ex ib IIC T4 Gb The logo—each element has a clear meaning: IIC Indicates that the equipment is suitable for gas groups with the highest explosion risk, such as hydrogen and acetylene. T4 The maximum surface temperature of the equipment shall not exceed 135℃ , meeting the safety margin requirements of the vast majority of chemical process scenarios.
II. Verification of Explosion-Proof Certification: Three Key Areas Must Be Fully Addressed
Explosion-proof certification is not simply a matter of whether a certificate exists; during the review process, the purchaser should verify each of the following three points:
- Comprehensive product coverage. Some procurement personnel focus solely on the explosion-proof certification for base stations, overlooking wearable devices such as worker ID cards and beacons. In fact, every hardware unit entering an explosion‑proof area must hold the corresponding certification. Suppliers are required to provide explosion‑proof certificates for the entire product lineup—including base stations, worker ID cards, and beacons; failure to do so renders the offering non‑compliant.
- The equipment category must match the hazardous area. Different explosion-proof zones have varying requirements for equipment categories. 0 District needs Ex ia Level, 1 District needs Ex ib or Ex d Level. In chemical engineering scenarios, it is generally recommended to select Ex ib IIC T4 Gb Intrinsically safe equipment of Class I and higher, and verify against the actual characteristics of the installation area.
- Original certificates and verifiability. Suppliers are required to provide the original explosion-proof certificate issued by a national-level testing institution, confirming that the applicable standard is… GB/T 3836 Series. Each certificate can be verified for authenticity and validity on the National Certification and Accreditation Information Public Service Platform; images in promotional materials have no legal effect.
III. After obtaining explosion-proof certification, three core competencies must still be assessed.
Explosion-proof certification addresses compliance and market access, but whether a system is stable and reliable in real-world applications depends on its technical design, environmental adaptability, and system integration capabilities.
From a technical architecture perspective, chemical process environments feature numerous metal structures and severe signal reflections, placing high demands on the positioning system’s anti-interference capabilities. Hangfei Optoelectronics employs… UWB High-precision positioning and Bluetooth wide-area coverage, LoRa A multimodal fusion solution combining long-distance backhaul: deployed in core high-risk areas such as reaction vessels, tank farms, and loading/unloading zones. UWB Beacons enable centimeter-level positioning; Bluetooth beacons are deployed in typical production areas to achieve… 3 To 5 Regional-level perception of rice; utilizing LoRa Backhaul reduces the installation workload of explosion-proof cabling. Combined with our proprietary circular-polarization directional antenna technology, it effectively mitigates signal drift in complex environments.
In terms of protection ratings and durability, corrosive gases, washdown water, and accidental impacts at chemical plant sites place stringent demands on equipment. Positioning tags and base stations should be equipped with… IP67 With protection ratings of IP67 and higher, they are waterproof, dustproof, and shock-resistant. The base stations, chest badges, and beacon housings from Hangfei Optoelectronics all meet IP67 , the directional explosion-proof positioning beacon has reached IP68。
In terms of system integration, positioning systems should not operate in isolation. Through standardization… API Interface; the system can integrate with video surveillance, access control, fire protection, and… DCS Once the existing systems achieve data interoperability and coordinated response, Hangfei Optoelectronics will provide standardized solutions. API , able to interface MES 、 WMS 、 ERP Enterprise information systems are deployed to establish a comprehensive security framework that integrates explosion-proof hardware, proactive early warning, and coordinated response mechanisms, enabling functions such as electronic fence boundary‑crossing alerts, abnormal‑behavior notifications, and one‑click… SOS Features such as emergency assistance and alarm‑triggered video linkage ensure that location data is effectively leveraged for safety management.
IV. Three Recommendations for Procurement Managers at Chemical Enterprises
First, make explosion-proof certification a mandatory requirement in the tender documents. Clearly stipulate in the technical specifications that all products in the series must be accompanied by original national-level explosion-proof certificates, and specify that the certificate numbers can be verified on the official platform. Do not base your decision solely on product brochures; during acceptance, conduct an on-site physical verification.
Second, select suppliers that have been rigorously tested in real-world chemical‑process environments. Laboratory data alone cannot fully reflect on‑site performance; peer application case studies and on‑site visits are effective ways to assess a supplier’s true capabilities.
Third, make decisions from a full lifecycle cost perspective. The battery life of personnel‑tagged devices directly impacts subsequent maintenance expenditures. Systems with incomplete explosion‑proof certifications, unstable positioning accuracy, or short battery life—though they may have lower initial purchase costs—often incur significantly higher ongoing expenses for battery replacements, handling false alarms, and addressing safety blind spots.
Chemical safety must never be overlooked. Selecting an appropriate personnel‑location system not only ensures compliance with regulatory requirements but also provides tangible protection for on‑site workers. Meanwhile, explosion‑proof certification is the most fundamental and critical step in this decision‑making process.