News Center

For personnel positioning in chemical plants, UWB positioning beacons are the preferred choice. How does Hangfei Optoelectronics ensure compliance with the mandatory AQ 3064 standard?


Category:

Author:

Aviation and Optical-Electronic Technology

Source:

www.hangfeigd.com

Release Date:

2026-09-24

2026 year 7 month 1 Day, Ministry of Emergency Management AQ 3064.3-2025 《 “ Industrial Internet + Safety in the Production of Hazardous Chemicals ” Construction Standards   The 3 Section: Personnel Location—has officially come into mandatory effect. For hazardous chemical enterprises involving major hazard sources, personnel location systems have from… “ Optional item ” Became “ Required question ”。

However, the challenges of positioning in chemical‑process environments are well known within the industry: dense arrays of metal tanks and vessels, severe electromagnetic interference, stringent explosion‑proof requirements, and virtually impossible wiring and installation. Conventional solutions either lack sufficient accuracy or incur exorbitantly high deployment costs.

The answer from Henan Hangfei Optoelectronics is: Use UWB Positioning beacons serve as precision reference points, a fusion‑based solution reduces costs, and a wire‑free design overcomes construction‑related challenges.

I. Why is it UWB Positioning beacon?

UWB (Ultra-wideband) technology transmits data via nanosecond‑scale narrow pulses, achieving extremely high temporal resolution and offering three irreplaceable advantages in chemical‑process applications:

First, the accuracy is sufficient. Industrial-grade UWB Positioning accuracy can reach 10-30 centimeters, far exceeding AQ 3064 For high-risk areas “ Sub-meter level ” A strict requirement: the system can accurately determine which reactor a worker is standing in front of and whether they have crossed the safety red line.

Second, it boasts strong anti-interference capabilities. The chemical workshop features a dense network of metal piping, resulting in severe signal reflections. UWB The signal’s power spectral density is extremely low, and its ability to distinguish multipath reflections far exceeds that of Bluetooth and… Wi-Fi It can still maintain stable ranging in non-line-of-sight environments.

Third, the latency is low enough. UWB End-to-end latency can be kept within 100 Within milliseconds, the positioning data upload frequency meets the standard requirements. “ Not less than 30 Next / minute ”。

Hangfei Optoelectronics’ optoelectronics UWB Beacon support 6240MHz-6739.2MHz Frequency band, communication range greater than 100 Rice, using TDOA The arrival‑time‑difference algorithm enables positioning and solution computation, maintaining high signal availability even under conditions of severe metal interference in chemical plants.

II. AQ 3064 Standard, Hangfei Optoelectronics Optoelectronics UWB How do you connect the positioning beacon?

AQ 3064.3-2025 Clear quantitative metrics have been established for personnel positioning systems, and Hangfei Optoelectronics’ solution has addressed each standard item by item since the very beginning of its design:

Accuracy grading meets the standard. Standard requires red / Orange high-risk areas must have sub-meter-level accuracy, blue / Static error in the yellow region ≤±3 Rice, dynamic ≤±5 Meters. The Hangfei Optoelectronics solution is deployed in high-risk areas. UWB Positioning beacons deliver sub-meter‑level accuracy, while Bluetooth beacons provide meter‑level coverage in typical areas. Deployment is tailored to regional risk levels, ensuring regulatory compliance while avoiding unnecessary capital expenditure.

It has full explosion-proof certification. Equipment installed in explosive‑hazard areas must obtain national explosion‑proof certification; this is a requirement for safety supervision and acceptance inspections. “ Veto item ” . Hangfei Optoelectronics UWB The positioning beacon is equipped with Exib IICT4 Gb / Exib IIICT130 Db Explosion-proof rating, with a protection rating reaching IP68 , which can be directly deployed on 1 district, 2 Zone for explosive atmospheres.

Data retention compliance. The standard requires that positioning data be stored for no less than 1 Year, supports real-time uploading to chemical industrial parks. The aerial photovoltaic system enables historical trajectory playback and cross-day queries, with a data retention period that meets regulatory requirements, and provides standardized… API The interface is integrated with the campus platform.

Functional integration is fully in place. The standard emphasizes that personnel positioning must not be “ Isolated Island System ” , it must be deeply integrated with special‑operation approval, electronic perimeter fencing, and early‑warning/alarm systems. The aerial photovoltaic system has already been connected to the electronic work‑permit system. API Docking, with automatic verification of the presence of operational personnel and supervisors, “ Construction cannot commence if the location does not match. ”。

III. The Real Barrier: No Wiring Required, No Production Downtime

Anyone in the chemical industry knows what it means to run a cable through a plant area: obtaining a hot‑work permit, installing explosion‑proof conduits, securing approval for cable trays, and scheduling a shutdown window. —— Installing a single base station can take up to a week.

Aviation and Optical-Electronic Technology