Personnel Positioning System Installation and Management Specifications Requirements – Real-Time Positioning of the Personnel Positioning System
The installation and management specifications for personnel positioning systems cover multiple aspects, including equipment installation, system commissioning, routine maintenance, personnel management, data security, and emergency response. The specific requirements are as follows:
I. Equipment Installation Standards
- Deployment of Remote Stations and Base Stations
- Personnel positioning system Sub-stations are installed at locations such as shaft entrances, access points to key areas, restricted zones, roadway junctions, and the entrances and exits of emergency refuge facilities, thereby meeting the requirements for monitoring personnel movement and directional guidance.
- Base stations shall be installed at a height of no less than 3 meters, with spacing ranging from 30 to 300 meters (adjusted according to the required signal coverage), and their antennas must be positioned at least 30 centimeters away from tunnel or roadway walls. Mounting shall be secured using clamps to prevent metal interference.
- Signal transceivers are deployed at the tunnel portal, with a coverage radius of ≥250 meters, and wireless bridges are installed concurrently to enable data transmission between the tunnel interior and exterior.
- Identification Card and Power Management
- All personnel entering the mine must carry an identification card or a wireless communication device with positioning capabilities; entry is strictly prohibited without such a card.
- Identification cards must not be opened without authorization, and any card found to be malfunctioning must not be used. The total number of fully functional identification cards shall be at least 10% greater than the total number of regular personnel; for cards not assigned to specific individuals, the total number shall be at least 10% greater than the maximum number of personnel permitted to enter the mine per shift.
- The power supply line’s load‑carrying capacity must be tested to prevent equipment failures caused by voltage instability. If the backup power source cannot ensure continuous operation for one hour after a grid outage, it should be replaced promptly. The entry point of the cable entering the mine shall be equipped with lightning protection measures.
II. System Commissioning and Operation Specifications
- Equipment commissioning
- Before use, the equipment shall be commissioned in accordance with the product’s instruction manual and operated on‑line for 24 hours; it may only be put into service upon passing inspection. Explosion‑proof equipment must undergo successful inspection and bear a certificate of conformity before being deployed underground.
- Modify the base station IP address and record its ID, ensuring it matches the server-side IP range. Enter the base station coordinates (with an error margin of ≤10 cm); incorrect coordinates will result in positioning drift. Import CAD/BIM maps and calibrate the coordinate system to align with the base station’s actual location.
- System Operation
- The system host and networked hosts shall be configured with dual‑ or multi‑node redundancy to ensure 24/7 continuous operation. In the event of a failure of the primary host, the standby host shall be brought online within five minutes.
- The central station shall be supplied by a dual-circuit power system and equipped with an online uninterruptible power supply (UPS) capable of providing at least two hours of backup power. The equipment must have reliable grounding and lightning protection, be outfitted with network security devices such as firewalls, and utilize recording-enabled telephones.
- The central control station is staffed around the clock. The on-duty operator shall closely monitor all information displayed on the monitors, meticulously record the operating status of each system component, complete the operation log, print daily (shift) monitoring reports, and submit them to the mine manager and relevant responsible personnel for review.
III. Standards for Daily Maintenance and Management
- Equipment maintenance
- Safety monitoring personnel shall be on duty around the clock, inspect equipment and cables daily, promptly address any issues discovered, and report the outcomes of such actions to the central control station.
- When equipment malfunctions, it shall be addressed promptly; during the故障 period, manual monitoring shall be implemented, and a fault registration form shall be completed.
- The central station shall back up its data every three months, and the backup data shall be retained for at least one year. Drawings and technical documentation shall also be retained for at least one year.
- Personnel Management
- Monitoring personnel and central station operators shall be duly trained, certified, and qualified to perform their duties.
- Establish technical documentation, including equipment and instrument ledgers, equipment failure registration forms, maintenance records, inspection logs, central station operation logs, daily (shift) monitoring reports, and monthly equipment utilization reports.
IV. Data Security and Emergency Response Guidelines
- Data Security
- System Personnel Positioning Sensitive data such as personnel locations and skill levels are stored in encrypted form, with tiered access control—e.g., only production supervisors can view skill levels.
- The system shall feature automatic fault diagnosis, capable of identifying faulty equipment and pinpointing the specific reader or card‑reading substation. It shall automatically display alarm messages and log the time of the fault along with the affected device, enabling subsequent query and printing.
- Emergency Response
- Upon receiving an alarm, the on-duty operator shall immediately notify dispatch and the on-duty supervisor. Dispatch and the on-duty supervisor shall promptly implement appropriate measures, and the outcome of the response shall be documented and filed.
- Organize emergency response drills to test the system’s reaction time in scenarios such as landslides and fires.